GF Signet 3-2818-1 Conductivity Resistivity Electrode
Elektroda Konduktivitas/Resistivitas GF cocok untuk berbagai aplikasi mulai dari pemantauan kualitas air dengan kemurnian tinggi hingga asam dan basa lemah, PFI Watermaker importir dan supplier GF Signet 3-2818-1 Conductivity Resistivity Electrode terlengkap menyediakan berbagai spare part water treatment dengan kualitas dan harga terbaik
GF Signet Conductivity Resistivity Electrodes
Signet GF Conductivity/Resistivity electrodes are designed to provide versatile installation and accurate sensing across a broad, dynamic range.
The GF Conductivity/Resistivity electrodes are suitable for a variety of applications ranging from high-purity water quality monitoring to weak acids and bases.
Specification Conductivity/Resistivity
Wetted Materials: 316 SST or Titanium
Process Connection Choices: 3/4 inch threads for In-line or Submersion, 1.5 inch Sanitary Tri-clamp flange and 2 inch Sanitary Tri-clamp flange
Cell constants and corresponding measuring ranges: 0.01 cm-1 / 0.55 to 100 μS (18.3 mΩ to 10 KΩ)
0.1 cm-1 / 1 to 1000 μS (1 mΩ to 1 KΩ)
1.0 cm-1 / 10 to 10,000 μS (5 to 5,000 ppm)
10.0 cm-1 / 100 to 200,000 μS (50 to 100,000 ppm)
20.0 cm-1 / 200 to 400,000 μS (100 to 200,000 ppm)
Compatible Instruments: Signet Instrument Types: 8850, 8860 8900, 9900 or the 9950 with the 2850 Sensor Electronics
Thread styles are reversible threads or fixed threads
Versatility
Easy-to-use sensors for process and pure water applications are available in two different families with a selection of electrode materials and process connections.
Accuracy and reliability
Two-electrode sensors are built with a controlled surface finish to ensure measurement accuracy and repeatability. Reliability is guaranteed thanks to individual testing of cell constant to ensure the highest possible measuring accuracy.
Sensor electronics
GF Signet 2850 Conductivity/Resistivity Sensor Electronics are available in various configurations for maximum installation flexibility and are also compatible with all GF Signet conductivity electrodes.
Wide range of applications
They are usable in multiple types of applications, from pure water treatment to cooling tower and boiler protection, salinity, aquatic animal life support systems and more.
Untuk permintaan penawaran GF Signet 3-2818-1 Conductivity Resistivity Electrode silahkan hubungi kantor kami
Alamat kontak
PT PROFILTER INDONESIA
Ruko Blok G/54 – Gudang A/01
Jl.Canadian Broadway
Kawasan Pergudangan Commpark – Kotawisata – Cibubur
Phone : +6221 84937329 , 84937805 , 22962668
WhatsApp : +62 813-8506-6789
Email : sales@profilterindonesia.com